Solar panel degradation calculator: capacity and energy over a PV plant's life

Solar panel degradation calculator: 1% in the first year and 0.4% a year leaves 87.4% at year 30. Set your own rates to see lifetime energy and the 80% point.

7 min read

PV degradation calculator

First-year degradation
Annual degradation from year 2
Lifetime

Model

Capacity left after 30 years

87.4 %

Lifetime energy vs no degradation

93.4 %

Capacity stays at or above 80 % for all 30 years.

Capacity lost since installation, End of year 0 to End of year 30. Capacity lost by end of year, latest 12.6 %.

Capacity lost since installation
YearCapacity lost by end of year
End of year 00.0 %
End of year 11.0 %
End of year 21.4 %
End of year 31.8 %
End of year 42.2 %
End of year 52.6 %
End of year 63.0 %
End of year 73.4 %
End of year 83.8 %
End of year 94.2 %
End of year 104.6 %
End of year 115.0 %
End of year 125.4 %
End of year 135.8 %
End of year 146.2 %
End of year 156.6 %
End of year 167.0 %
End of year 177.4 %
End of year 187.8 %
End of year 198.2 %
End of year 208.6 %
End of year 219.0 %
End of year 229.4 %
End of year 239.8 %
End of year 2410.2 %
End of year 2510.6 %
End of year 2611.0 %
End of year 2711.4 %
End of year 2811.8 %
End of year 2912.2 %
End of year 3012.6 %

Constant rates, no wear-out phase, no repowering. Use module rates for modules alone; a fleet performance-loss rate already includes soiling, availability and inverter ageing, so don't add those again.

Key points

  1. Per Trina Solar's and Jinko's 2025 n-type datasheets, modules guarantee 99% of rated power after year 1 and 87.4% or 88.85% after year 30 (0.4% or 0.35% a year, linear).
  2. In Jinko's p-type Tiger Pro datasheet (as of October 2026), a 2% first-year loss then 0.55% a year guarantees 84.8% of rated power after year 25.
  3. Jordan and Kurtz's 2013 review of nearly 2,000 field rates found a median of 0.5%/year (mean 0.8%/year), while Jordan et al.'s 2022 US fleet study of 4,915 inverters found a median whole-system loss of 0.75%/year.
  4. In a linear model using Trina Solar's 2025 warranty terms (1% first year, 0.4%/year), a 30-year case leaves 95.40%, 91.40% and 87.40% of capacity at years 10, 20 and 30 and delivers 93.41% of the energy of an undegraded plant.
  5. In a linear model at the 2022 US fleet median of 0.75%/year (a whole-system rate, Jordan et al.), capacity falls to 77.5% by year 30, crosses 80% in year 27, and lifetime energy is 88.75% of the undegraded case.
  6. In a 30-year linear warranty-style case (Trina Solar's 2025 terms), raising the annual rate from 0.4% to 0.5% lowers lifetime energy by 1.4 percentage points; one extra point of first-year loss lowers it by 0.98 points.

Current n-type module warranties guarantee 99% of rated power after year 1 and 87.4% to 88.85% after year 30. Measured US plants lose a median 0.75% of output a year, a whole-system rate. This solar panel degradation calculator turns either assumption into capacity by year, a lifetime energy factor and the year output falls below 80%.

What does this solar panel degradation calculator compute?

It estimates how much of a photovoltaic (PV) plant's starting direct current (DC) capacity remains each year, and how much lifetime energy that costs. Four inputs set the case: first-year degradation (0 to 3%), annual degradation from year 2 (0 to 1.5%/year), lifetime (10 to 40 years) and the model, linear or compound.

The arithmetic is fully stated. Capacity starts at 100% and is a share of the day-one value:

End of year 1 = 100 - first-year degradation
Linear:   end of year y = end of year 1 - rate × (y - 1)
Compound: end of year y = end of year 1 × (1 - rate/100)^(y - 1)
Yearly average = (start-of-year capacity + end-of-year capacity) / 2
Lifetime energy factor = mean of the yearly averages

The tool shows three results and a chart. The results are the capacity left after the chosen lifetime (%), the lifetime energy compared with no degradation (%), and the first year in which end-of-year capacity drops below 80%, or a note that it stays at or above 80%. The chart shows capacity lost by the end of each year. Heat is a separate, reversible loss with its own temperature loss calculator.

What is the difference between module degradation and system performance loss rate?

Module degradation is the loss of a module's own power over time. System performance loss rate (PLR) is the decline in a whole plant's output, so it also captures availability, soiling and snow losses. Published numbers mix the two, so the sample matters as much as the median.

StudySampleHeadline rateNotes
Jordan and Kurtz (2013)Nearly 2,000 module and system rates from field testsMedian 0.5%/yearMean 0.8%/year; 78% of rates below 1%/year
Jordan et al. (2022)4,915 inverter channels at US plantsMedian 0.75%/yearSite median 0.68%/year; 90% of inverters lose less than 1.90%/year; 0.48%/year in cooler climates, 0.88%/year in hotter ones
Deline et al. (2024)Same fleet grown to 8.5 GW, soiling separated outAbout 0.5%/year on averageRemoving soiling made the median about 0.25%/year less severe

The Jordan and Kurtz review comes from NREL (now the National Laboratory of the Rockies). Its rates exclude short-term light-induced loss. It surveys the literature rather than sampling at random, and modules that degrade fast are less likely to stay in the field to be reported.

The 2022 figures come from the PV Fleet Performance Data Initiative, which collected data from more than 7.2 GW, 1,700 sites and 19,000 inverters.

What causes modules to degrade?

Four mechanisms matter most for crystalline silicon. Kiwa PVEL, an independent module test lab, reports all four in its 2026 Scorecard (figures as of October 2026). The cell designs compared are passivated emitter and rear cell (PERC) and tunnel oxide passivated contact (TOPCon).

MechanismWhat happensKiwa PVEL result, as of October 2026
Light-induced degradation (LID)Early loss in boron-doped cells; stabilises soon after deploymentMedian 0.4% for TOPCon, 0.6% for PERC
Light and elevated temperature induced degradation (LeTID)Slow loss in warm, sunlit modules, mostly early PERCMedian 0.1%, maximum 1.4%; early reports near 10% fell to 1% to 2% or less in an NREL-led study
Potential-induced degradation (PID)Loss from system voltage, mainly in ungrounded systems83% of 2025 designs lost under 2%
Ultraviolet-induced degradation (UVID)UV damage in some TOPCon modulesMedian 3.0% in the lab test; one cell supplier's designs lost 14.1% and 3.6%

UVID is the least settled. Fraunhofer ISE finds that standard UV tests overstate field loss unless modules are stabilised under light first, leaving up to 5% after a 60 kWh/m² dose. Kern et al. measured 2.3% to 3.2% non-recoverable loss. Soiling and hail are losses, not degradation: soiling is recoverable, and hail damage is an event, not a rate.

What do manufacturer performance warranties promise?

Datasheets give a first-year loss, a yearly loss after that and a guaranteed power at the end of the term. Current n-type modules promise 1% then 0.35% to 0.4% a year over 30 years. The p-type and PERC datasheets below promise 2% then 0.55% a year over 25 years.

ModuleCell typeTermFirst yearEach year afterPower guaranteed at the end
Trina Vertex N TSM-NEG21C.20n-type TOPCon30 years1%0.4%87.4%
Jinko Tiger Neo 3.0 JKM460-485N-48QL6-DBn-type TOPCon30 years1%0.35%88.85%
Jinko Tiger Pro 72HC JKM530-550M-72HL4p-type mono-crystalline25 years2%0.55%84.8%
Canadian Solar HiKu6 CS6W-530MS to 555MSmono PERC25 years2%0.55%Not printed

A linear warranty is a straight line from the first-year floor to the end-of-term floor. LONGi's limited warranty writes one tier as a formula for power in year N, from 2 to 30:

Power(N) >= Nominal power × (1 - (1% + 0.4% × (N - 1)))

That tier guarantees 99% in year 1 and 87.4% in year 30, and the calculator's linear model draws the same line. The figures are floors, not forecasts. Terms vary by product, glass type and market, so the warranty text for the specific module governs. Kiwa's median LID losses (0.4% and 0.6%, as of October 2026) sit well inside the first-year allowances of 1% and 2%.

What do the worked examples show?

Two cases run through the model for 30 years with the linear option. The warranty case uses the 1% and 0.4%/year printed above, which are module rates. The fleet case uses the 0.75%/year median, a whole-system performance-loss rate that already includes soiling, availability and inverter ageing. Entering 0.75% as the first-year loss too is an analytical choice, so that every year loses the same amount.

CaseFirst yearAnnualYear 10Year 20Year 30Lifetime energy factorFirst year below 80%
Warranty-style n-type1%0.4%95.40%91.40%87.40%93.41%None in 30 years
Fleet median (system rate)0.75%0.75%92.50%85.00%77.50%88.75%Year 27

The warranty case reproduces the 87.4% on the Trina datasheet. The fleet case is an extrapolation, because the initiative asks participants for at least 3 years of data, far short of 30. With the compound option, the fleet case ends year 30 at 79.78% instead of 77.5%, because each year's loss is a share of a shrinking base.

Small changes in inputs matter. In the warranty case, raising the annual rate from 0.4% to 0.5% lowers the lifetime energy factor by 1.4 points. One more point of first-year loss lowers it by 0.98 points.

Why does the calculator open on 1%, 0.4%, 30 years and linear?

These are the values printed on current n-type datasheets (Trina) and in the warranty tier above. Year 30 therefore returns 87.4%, a figure anyone can check against a datasheet. They describe a contractual floor, not a measurement. For a whole-system case, enter 0.75 and 0.75, the fleet median; the first-year 0.75 is an analytical choice.

How does degradation feed into yield and LCOE?

Lifetime energy equals the undegraded annual energy, times the years, times the lifetime energy factor. A plant that would make 1,000 MWh a year without degradation makes 28,023 MWh over 30 years in the warranty case and 26,625 MWh in the fleet case. First-year energy itself depends on irradiation, capacity and the performance ratio (PR), explained in capacity factor vs performance ratio.

The levelised cost of electricity (LCOE) divides lifetime cost by lifetime energy, so faster degradation raises it. Later years count for less once discounted, so the effect on LCOE is smaller than the effect on undiscounted energy. The LCOE calculator works with that ratio of cost to energy.

What this means for owners and investors

The two cases show the spread: 87.4% against 77.5% at year 30, and 93.41% against 88.75% in lifetime energy. The degradation assumption behind an energy forecast therefore deserves its own line, stated as module or system. Test results also differ by design, as Kiwa's 3.6% to 14.1% UVID range for one cell supplier shows (as of October 2026), so product-specific data says more than an average. Sources and conventions for this site are on the methods and data sources page.

Limits of the calculator

  • Constant rates. It uses one first-year loss and one annual rate. LID, LeTID and UVID depend on time and partly recover, and fleet rates vary with climate (0.48%/year cooler, 0.88%/year hotter).
  • No wear-out phase. Jordan and Kurtz note that linearity and the effect of climate were not settled. Late-life acceleration is not modelled.
  • No repowering. Module swaps and inverter replacement are outside the model.
  • Module rates for modules, system rates for systems. Warranty values describe module power under standard test conditions. A fleet performance-loss rate already includes soiling, availability and inverter ageing, so do not add those again. With a module rate, they are outside the model.
  • Yearly averaging. Averaging start and end capacity approximates each year's energy.

Results are estimates, not a performance guarantee or engineering advice.

What is a normal solar panel degradation rate per year?

Current warranties allow 0.35% to 0.55% a year after the first year. A literature review found a median of 0.5%/year, and a US fleet study found a median whole-system loss of 0.75%/year.

Is the first-year drop part of the annual rate?

No. Warranties state the first-year loss separately (1% for current n-type modules, 2% for the p-type and PERC datasheets above). Jordan and Kurtz's rates also exclude short-term light-induced degradation, so the calculator takes first-year loss as its own input.

Does a panel lose 20% of its power in 25 years?

Not under a warranty-style case: the Jinko Tiger Pro datasheet guarantees 84.8% at year 25. At the US fleet median of 0.75%/year, a system is at 81.25% in year 25 and crosses 80% in year 27.

Should I use linear or compound degradation?

Warranties are linear, so linear matches them. Field data has not settled the shape. At 0.75% first year and 0.75%/year, the compound option ends year 30 at 79.78% against 77.5% for linear.
  1. Photovoltaic degradation rates, an analytical review (Jordan and Kurtz, Progress in Photovoltaics 21(1), 2013), NREL via OSTI, 2013-01
  2. Photovoltaic fleet degradation insights (Jordan et al., Progress in Photovoltaics 30(10), 2022), NREL via OSTI, 2022-04-24
  3. Availability and Performance Loss Factors for U.S. PV Fleet Systems (Deline et al., NREL/TP-5K00-88769), NREL via OSTI, 2024-02-26
  4. PV Fleet Performance Data Initiative, National Laboratory of the Rockies (NLR)
  5. Energy Department renames NREL the National Laboratory of the Rockies, National Laboratory of the Rockies (NLR), 2025-12-01
  6. Results from an international interlaboratory study on light and elevated temperature-induced degradation in solar modules (Karas et al.), NREL, Progress in Photovoltaics 30, 2022, 2022-05-05
  7. Kiwa PVEL 2026 PV Module Reliability Scorecard: LID + LETID test, Kiwa PVEL, 2026-05-27
  8. Kiwa PVEL 2026 PV Module Reliability Scorecard: PID test, Kiwa PVEL, 2026-05-27
  9. Kiwa PVEL 2026 PV Module Reliability Scorecard: UVID test, Kiwa PVEL, 2026-05-27
  10. Fraunhofer ISE evaluates common UV tests for TOPCon modules for practical relevance, Fraunhofer ISE, 2025-04-10
  11. UV-induced degradation and associated metastability in TOPCon photovoltaic modules (Kern et al., Progress in Photovoltaics 34(5), 2026), NLR via OSTI, 2026-01-08
  12. Vertex N TSM-NEG21C.20 695-725 W datasheet (version 2025_B), Trina Solar, 2025
  13. Tiger Neo 3.0 JKM460-485N-48QL6-DB datasheet (F2, EU), JinkoSolar, 2025-09
  14. Tiger Pro 72HC JKM530-550M-72HL4 datasheet, JinkoSolar
  15. HiKu6 Mono PERC CS6W-530MS to 555MS datasheet (v2.7), Canadian Solar (CSI Solar), 2026-01
  16. Limited warranty for LONGi Hi-MO 9, Hi-MO 7 and others solar modules (distributed generation market), LONGi

Results are estimates from a simplified model. They are not engineering, investment or financial advice. How this site works with data: methods and sources.